- Year
- 2009
- Stock no.
- 7582962
Drager Babylog 8000 plus neonatal intensive care ventilator (2009)
Neonatal intensive care ventilator Drager Babylog 8000 plus; IPPV/IMV, SIPPV, SIMV, PSV and CPAP modes, Volume Guarantee, optional HFV.
Price on request
Add this device to your quote list to request its price.ТОО "FSA KZ (ФСА КЗ)", Almaty, Kazakhstan, BIN 210940036794
- Brand
- Drager
- Model
- Babylog 8000 Plus
- Category
- ICU ventilators
Specifications
| Dräger Babylog 8000 Plus Neonatal Ventilator (year of manufacture: 2009) | A trusted cornerstone for neonatal intensive care units, delivering gentle and precise respiratory support for the most vulnerable patients. Engineered for premature and newborn infants, this ventilator combines advanced technology with user-friendly controls to ensure optimal ventilation with minimal stress. Its compact design, reliable performance and specialized neonatal features make it an essential tool for NICU clinicians aiming to provide life-saving care with confidence and ease. |
|---|---|
| Ventilation Modes | CPAP, IMV, SIMV and volume-controlled ventilation |
| Flow Range | Adjustable for neonatal precision, up to 30 L/min |
| Monitoring | Real-time airway pressure, flow and volume monitoring |
| Display | Clear LCD screen with intuitive controls |
| Why choose the Dräger Babylog 8000 Plus Ventilator? Year of manufacture | 2009 |
| Tailored Neonatal Ventilation | Designed specifically for premature and newborn infants, it delivers gentle, precise ventilation to protect delicate lungs while ensuring effective respiratory support. |
| Advanced Monitoring | Real-time data on airway pressure, flow and volume empowers clinicians to make informed adjustments, optimizing outcomes in critical neonatal care. |
| User-Friendly Design | The intuitive LCD interface simplifies operation, allowing NICU staff to focus on patient care even during high-pressure situations. |
| Compact and Reliable | Its space-saving design fits seamlessly into busy NICU environments, while its robust engineering ensures consistent performance for long-term use. |
| Refurbished Unit | Fully refurbished and rigorously tested, this 2009 model upholds Dräger's legacy of quality, delivering dependable care for neonatal patients. |
| Refurbished Dräger Babylog 8000 Plus Ventilator (year of manufacture: 2009) | Certified for quality and ready for immediate use, this ventilator is a vital asset for neonatal care. |
Description
Includes:
- Babylog 8000 plus neonatal intensive care ventilator, year of manufacture: 2009
Key features
- Advanced neonatal ventilation: designed specifically for respiratory support of neonates and premature infants in intensive care environments.
- Multiple ventilation modes: supports IPPV/IMV, SIPPV, SIMV, PSV and CPAP ventilation modes.
- Volume Guarantee (VG): helps maintain a consistent preset tidal volume while adapting inspiratory pressure to changing lung conditions.
- High-frequency ventilation: provides an optional HFV function for specialized neonatal respiratory support.
- Pressure support ventilation: supports spontaneous breathing and can assist the weaning process.
- Compact design: practical configuration suitable for neonatal intensive care units (NICUs).
Technical highlights
Precise neonatal respiratory support
The Babylog 8000 Plus is engineered for sensitive neonatal ventilation, with accurate synchronization and monitoring of very small tidal volumes.
Flexible ventilation therapy
Its combination of conventional ventilation modes, Volume Guarantee, PSV, CPAP and optional HFV provides flexibility for different neonatal respiratory requirements.
Leak compensation and spontaneous breathing
Pressure support ventilation incorporates automatic leak compensation, helping maintain effective support while allowing the infant greater control over breathing.
Applications:
The Dräger Babylog 8000 Plus is suitable for
- Neonatal intensive care units (NICU)
- Premature and critically ill infants
- Neonatal respiratory distress management
- Invasive and non-invasive respiratory support
- Weaning from mechanical ventilation
- Specialized high-frequency ventilation
Key benefits
- Purpose-built neonatal ventilation
- Accurate and sensitive respiratory support
- Flexible ventilation modes
- Volume Guarantee for controlled tidal volumes
- Supports spontaneous breathing and weaning
- Compact and practical NICU design
- Established Dräger ventilation technology
Why choose the Dräger Babylog 8000 Plus?
The Dräger Babylog 8000 Plus Ventilator, a 2009 model, is a key instrument in neonatal intensive care, designed specifically for premature and newborn infants. This ventilator offers modes such as CPAP, IMV, SIMV and volume-controlled ventilation, delivering precise respiratory support with minimal stress on delicate lungs. Its compact, user-friendly design ensures seamless integration into NICU environments, supporting clinical staff with intuitive LCD controls and real-time monitoring of airway pressure, flow and volume.
Engineered for reliability, the Dräger Babylog 8000 Plus provides consistent performance, making it a trusted choice for healthcare providers. It is equipped with advanced technologies, including BabyFlow® nasal CPAP and pressure support ventilation, enhancing the safety and efficacy of neonatal care. The ventilator's design simplifies operation and allows healthcare professionals to focus on patient care, even in high-pressure situations.
This refurbished unit has been fully restored and rigorously tested, ensuring it meets Dräger's high standards of quality. The Dräger Babylog 8000 Plus Ventilator represents a combination of advanced technology and user-friendly operation, making it a vital asset in any NICU setting.
Similar devices