Electrical impedance tomography system for continuous noninvasive bedside monitoring of regional ventilation distribution; silicone belt with 16 electrodes.
Price on request
Add this device to your quote list to request its price.ТОО "FSA KZ (ФСА КЗ)", Almaty, Kazakhstan, BIN 210940036794
The device is designed for continuous noninvasive monitoring of regional ventilation distribution. Tracking changes in end-expiratory lung impedance (EELI, dEELI) is used to assess the effectiveness of lung recruitment and to select the optimal PEEP. Information on lung function is presented as images, waveforms and numerical parameters.
Trend recording up to 120 min. Ventilation parameters can be imported from Draeger Evita family ventilators. Operation on the built-in battery for 10 min. Service life of the electrode belt and patient cable is at least 12 months. Device maintenance interval is 2 years. No disposable consumables are required for monitoring.
Features
Real-time visualization of the entire ventilation cycle
A lung-protective ventilation strategy requires optimal setting of positive end-expiratory pressure and tidal volume. Selecting and maintaining these basic settings throughout the course of therapy is a challenging task even for an experienced physician. Global parameters reflecting the lungs as a whole do not provide a continuous picture of the patient's lung function. Without continuous regional data, assessing how different lung regions respond to a therapeutic intervention comes down to guesswork. The PulmoVista 500 electrical impedance tomograph lets you continuously and directly observe ventilation in different lung regions, optimizing individualized therapy.
Continuous, noninvasive bedside imaging
You can monitor lung function right at the bedside, even around the clock. A flexible silicone belt with 16 integrated electrodes is easily placed on the patient's chest and connected to the PulmoVista 500. No invasive or stressful procedures. No ionizing radiation. No patient transport.
The PulmoVista 500 allows assessment of the regional distribution of tidal volume during mechanical ventilation, as well as short-term changes in end-expiratory lung volume. You can see the results of therapeutic procedures and monitor them over time. As a result, the PulmoVista 500 helps you maintain optimal air distribution in the lungs and informs you of conditions such as atelectasis, lung overdistension, air trapping, pleural effusion or pneumothorax that may occur during mechanical ventilation.
In addition to generating images, the PulmoVista 500 electrical impedance tomograph produces global and regional impedance and parameter waveforms. It also shows trends in regional changes in end-expiratory lung air content and allows comparison of the current status with earlier measurements. This information helps you build a more complete picture and adhere to a lung-protective ventilation strategy throughout the course of therapy.