Fresenius 4008S classic hemodialysis machine
Hemodialysis machine with 10.4-inch TFT-LCD display, integrated blood pressure monitor (BPM), OCM clearance monitoring, DIASAFE plus filter and bibag dry bicarbonate.
Price on request
Add this device to your quote list to request its price.ТОО "FSA KZ (ФСА КЗ)", Almaty, Kazakhstan, BIN 210940036794
- Brand
- Fresenius
- Category
- Haemodialysis machines
Description
The ergonomic design and logical menu structure of the 4008S classic make operation easier and allow fast, intuitive programming of treatment parameters. Important treatment parameters are shown graphically on a 10.4-inch TFT-LCD monitor, which displays the parameters during the procedure and provides quick access to the treatment history.
The blood pressure monitor (BPM) is fully integrated, which also simplifies the work of medical staff. Combined with the therapy data management system (TDMS), daily dialysis practice can be organized more efficiently and effectively, with online data collection for each treatment and tools to manage the course of the procedure.
The online clearance monitor (OCM), in combination with the body composition monitor (BCM) that measures the urea distribution volume V, provides an accurate assessment of Kt/V consistent with conventional methods based on blood sample analysis.
Thanks to the adsorption properties of the Fresenius Polysulfone fiber membrane, the DIASAFE plus dialysis fluid filter retains endotoxins, allowing ultrapure dialysis fluid to be produced.
To avoid the potential risk of microbiological contamination through liquid bicarbonate concentrate, the bicarbonate buffer is always supplied as a dry substance.
Key features
A practical approach to quality treatment
Nearly every second patient with ESRD dies of cardiovascular disease. That is why cardioprotective hemodialysis is the core principle of Fresenius Medical Care as a dialysis care provider with more than 100 years of experience. Every step the manufacturer takes is aimed at minimizing cardiovascular risks and extending patients' lives. The 4008S classic continues the success story of the well-known 4008 series, combining the best quality of HD treatment with reliability and operational efficiency.
Proven quality
- The latest development in the highly successful 4008 series
- Improved dialysis fluid circuit with high-precision volume-controlled ultrafiltration
- Reliable hydraulics
Advanced treatment
- High-quality HD to protect your patient
- OCM (online clearance monitor)
- DIASAFE plus (dialysis fluid filter)
- bibag (dry bicarbonate concentrate)
- Single-needle mode or "click-clack" single-needle mode (SN or SN Click-Clack)
High operational efficiency
- Cost-effective use of resources
- Easy, fast and intuitive operation
- TDMS (therapy data management system)
- BPM (blood pressure monitor)
- CDS (central concentrate delivery system)
- AdaptedFlow*
* AdaptedFlow is not available in all countries.
Technical specifications
General data
- Dimensions (H x L x W)
- 1370 x 500 x 650 mm (including shunt interlock and base)
- Weight
- approx. 86 kg
Water supply
- Water inlet pressure
- 1.5-6.0 bar
- Water inlet temperature
- 5°C-30°C; for "integrated hot rinse" 85°C-95°C
- Maximum drain height
- 1 m
Concentrate supply
- Pressure
- 0-100 mbar; 1 m maximum suction height
- Central supply
- 1 central acid concentrate (optional), 0-500 mbar
Electrical data
- Power supply
- 100-240 V AC, 50-60 Hz
- Current consumption
- approx. 9 A (at 230 V) and 15 A (at 110 V)
- External connections
- network interface for data exchange with the therapy data management system (optional); input/output for connecting external auxiliary equipment; alarm input/output (e.g. for nurse call); home dialysis computer diagnostics
- Battery
- 18 V; 3 Ah (uninterruptible)
Extracorporeal circuit
Arterial pressure monitoring
Display range: -300 mmHg to +280 mmHg
Accuracy: ±10 mmHg
Resolution: 20 mmHg
Venous pressure monitoring
Display range: -60 mmHg to +520 mmHg
Accuracy: ±10 mmHg
Resolution: 20 mmHg
Transmembrane pressure monitoring
Display range: -60 mmHg to +520 mmHg
Resolution: 20 mmHg
Arterial blood pump
Blood flow range: 15-600 ml/min
Accuracy: ±10%
Resolution: 5 ml/min
- Single-needle system (optional)
- with 2 blood pumps, internal pressure control / pressure control with variable stroke volume (max. 50 ml/min)
- Air bubble detector
- ultrasonic transmission measurement in the blood line, additional optical monitoring of the venous clamp
- Heparin pump
- delivery range 0 to 10 ml/h; bolus function: max. 5 ml; bolus syringe size: 20 ml
Dialysis fluid circuit
- Dialysis fluid flow range
- selectable, 0, 300, 500, 800 ml/min
- AdaptedFlow* (selectable)
- dialysate flow adapted to effective blood flow
- Dialysis fluid temperature
- selectable, 35°C-39°C
Dialysis fluid conductivity
Range: 12.8-15.7 mS/cm (25°C)
Accuracy: ±0.1 mS/cm
Resolution: 0.1 mS/cm
Acid component of dialysis fluid
Mixing ratio: 1 + 27.6 (others possible)
Adjustment range: -8 to +8 mmol/l
Bicarbonate component of dialysis fluid
Default mixing ratio: 1 + 27.6 (others possible)
Adjustment range: -8 to +8 mmol/l
OCM (online clearance monitoring)
Clearance K accuracy: ±6%
- Dry bicarbonate concentrate
- bibag
- Dialysis fluid filter system
- DIASAFE plus
- Balancing accuracy
- ±0.1% depending on total dialysate volume
- Pressure holding test
- cyclic
Ultrafiltration
UF rate: 0-4000 ml/h (in 1 ml/h steps)
Pump volume accuracy: ±1%
Displayed parameters: UF goal, UF time, UF rate, UF volume
Blood leak detector
Sensitivity: ≤ 0.5 ml blood/min (Hct = 25) at max. flow of 800 ml/min
BPM (optional)
Display range:
- Systolic: 30 mmHg-280 mmHg
- Diastolic: 10 mmHg-240 mmHg
- MAP: 20 mmHg-255 mmHg
- Pulse: 20-245 bpm
- Accuracy
- ±3 mmHg
- Resolution
- 1 mmHg
Disinfection and cleaning programs (temperature/flow)
Rinse: 37 °C / 600 ml/min
Hot rinse (recirculation): 84 °C / 450 ml/min
Integrated hot rinse: 84°C / 450 ml/min
Cleaning with Sporotal 100 (recirculation): 37 °C / 600 ml/min
Heat disinfection with Diasteril/Citrosteril (recirculation): 84° C / 450 ml/min
Disinfection with Puristeril 340/plus (recirculation): 37 °C / 600 ml/min
Components and accessories
4008 type hemodialysis machine with accessories, version: 4008 S
1. Automatic line priming system - AUTOPRIME Option.
2. Installation kit for the automatic line priming system - AUTOPRIME modification kit.
3. BVM unit (monitor for hematocrit, volume change and blood circulation) - BLOOD VOLUME MONITOR Option.
4. Installation kit for the BVM unit - BLOOD VOLUME MONITOR modification kit.
5. BTM unit (monitor for controlling and maintaining thermal balance) - BTM Option.
6. Installation kit for the BTM unit - BTM modification kit.
7. BPM (automatic blood pressure and pulse monitor) - BLOOD PRESSURE MONITOR Option.
8. Installation kit for the automatic blood pressure and pulse monitor - BLOOD PRESSURE MONITOR modification kit.
9. Blood pump motor module (for single-needle dialysis) - SINGLE NEEDLE BLOOD PUMP Option.
10. Installation kit for the blood pump motor module - SINGLE NEEDLE BLOOD PUMP modification kit.
11. Dialysate sterilization system - DIASAFEplus Option.
12. Installation kit for the dialysate sterilization system - DIASAFEplus modification kit.
13. Filter for the dialysate sterilization system - DIASAFEplus.
14. Dialysate sterilization system - DIASAFE Option.
15. Installation kit for the dialysate sterilization system - DIASAFE modification kit.
16. Filter for the dialysate sterilization system - DIASAFE.
17. Hemodiafiltration add-on - ONLINE Option.
18. Hemodiafiltration add-on (installation kit) - ONLINE modification kit.
19. Hemodiafiltration add-on - ONLINE plus Option.
20. Hemodiafiltration add-on (installation kit) - ONLINE plus modification kit.
21. Filter for the hemodiafiltration system - ONLINE - HDF.
22. Bicarbonate dialysis unit - BIBAG Option.
23. Bicarbonate dialysis unit (installation kit) - BIBAG modification kit.
24. Adapter module for connecting the dry bicarbonate concentrate bag - BIBAG CONNECTION.
25. Bicarbonate dialysis unit - 3 MIX Option.
26. Bicarbonate dialysis unit (installation kit) - 3 MIX modification kit.
27. Add-on for HDF with ready-made substitution solutions - STANDART HDF-OPTION.
28. Add-on for HDF with ready-made substitution solutions (installation kit) - STANDART HDF modification kit.
29. Monitor for measuring effective clearance and Kt/V during dialysis - Online Clearance Monitor Option.
30. Monitor for measuring effective clearance and Kt/V during dialysis (installation kit) - Online Clearance Monitor modification kit.
31. Remote control unit - Remote Control Unit Option.
32. Remote control unit (installation kit) - Remote Control Unit Monitor modification kit.
33. Solution dosing device - SLEEP SAFE.
34. Concentrate mixing devices - GRANUMIX 107S, 507S.
35. Interface unit - INTERFACE BPM, BTM, BVM.
36. Solution temperature maintenance device - PD-THERMOSAFE Plus.
37. Arterial clamp unit - ARTERIAL CLAMP.
38. Set of 3 cuffs for the blood pressure monitor - SET 3 CUFFS FOR BPS.
39. Cuff for the blood pressure monitor - CUFF FOR ADULTS, BPS.
40. Pediatric cuff for the blood pressure monitor - CHILDREN CUFF FOR BPS.
41. Modified filter holder - FILTER HOLDER (MODIF.).
42. Dialyzer holder - DIALYZER HOLDER.
43. Dialysis table - DIALYSIS TABLE.
44. Operating mode indicator light - TRAFFIC LIGHT.
45. Machine tray - DIALYSIS TRAY.
46. Seca electronic scale, model 984 - SECA 984.
47. Seca electronic scale, model 954 - SECA 954.
48. Seca electronic scale, model 767 - SECA 767.
49. LDL sorption sets - DALI 750-SET, DALI 1000-SET.
50. Priming solution - PRIMERLOSUNG-SET.
51. Pressure gauge from -1 to +1.5 atm - PRESSURE GAUGE -1.0 TO +1.5 BAR.
52. Pressure gauge from 0 to 4 atm - PRESSURE GAUGE 0 TO 4 BAR.
53. Pressure gauge set for calibrating 4008 series machines - PRESSURE GAUGE SET CPL.
54. Universal digital pressure gauge - PRESSURE GAUGE HANDHELD DIGITAL.
55. Universal pressure gauge - PRUEFMANOMETER M. ANSCHL.
56. Digital pressure meter - PRESSURE GAUGE VDM100R.
57. Conductivity/temperature meter - TMP/TEMP. MEASURING UNIT.
58. Conductivity/temperature meter - Temperature/Conductivity Meter.
59. Adapter for the conductivity/temperature meter - ADAPT FOR COND/TEMP-METLF91.
60. Adapter for the conductivity/temperature meter - Adapter For Cond./Temp.-Meter.
61. Measuring tool - UNIVERSAL MEASURING DEVICE.
62. Venous drip chamber simulator - ADJUSTMENT STANDART.
63. Large tool set in a case - TOOL CASE F. EGUIP W HAND-TOOL.
64. Solenoid valve function tester - MAGNETIC VALVE FUNCTION TESTER.
65. Frequency counter - FREQUENCY COUNTER.
66. Wrench set - TORGUE WRENCH SET.
67. Multimeter with frequency counter - MULTIMETER FLUKE 87.
68. Wrench for installing/removing plug-in units - SOCKET WRENCH 4 MM.
69. Extension board - EXTENSION BOARD 96 PIN.
70. Valve status indicator - P/V-DISPLAY.
71. Universal meter - NEO-2-SYSTEM DIG. DIALYSIS-METER FOR 4008.
72. Dual-channel oscilloscope with memory - DUAL-CHANNEL SCOPE WITH MEMORY.
73. Large tool set in a case - TOOL CASE F. EGUIP W.
74. Adapter for 4008 series machines - LP 312 ADAPTER BOARD.
75. Measuring instrument - MEASURING INSTRUMENT.
76. Valve status indicator - P/V-DISPLAY.
77. Connection block for 4008 series machines - CONNECTION BLOCK CPL., 4008.
78. Arterial blood pump module - ART. BLOOD PUMP MODULE.
79. Multifunction block for 4008 series machines - MULTIFUNCTION BLOCK 4008.
80. CPL multifunction block for 4008 series machines - MULTFUNKTION BLOCK, CPL.
81. Monitor front panel - TOUCH PANEL.
82. Shunt box - SHUNT INTERLOCK.
83. Air detector module - LD-MODULE 22 mm.
84. Upgrade kit, software version installation - MODIF. KIT, CPL. SOFTWARE.
85. Front panel - FRONT PANEL.
86. BiBag plug-in module - HOLDING PLATE W.CONNECTOR.
87. Extension board for 4008 series machines - EXTENSION BOARD 96 PIN.
88. Interface board - INTERFACEBOX.