BECKMAN COULTER AU 480 biochemistry analyzer

Fully automated biochemistry analyzer: 400 photometric tests per hour, up to 800 tests per hour with ISE.

Price on request

Add this device to your quote list to request its price.

ТОО "FSA KZ (ФСА КЗ)", Almaty, Kazakhstan, BIN 210940036794

Brand
Beckman Coulter
Model
AU 480
Category
Other products
Country of manufacture
Germany

Description

The AU480 biochemistry analyzer performs excellently as the main biochemistry analyzer for low- and medium-throughput laboratories, and as a specific protein analyzer or STAT analyzer for high-volume laboratories. Throughput of up to 400 photometric tests per hour (up to 800 with ISE), an increased number of completed analyses, reduced sample consumption and ease of operation make the AU480 an efficient tool.

Analytical system
fully automated random-access biochemistry system with STAT sample loading
Analytical principle
spectrophotometry and potentiometry
Assay types
end point, kinetic, fixed time and ISE (indirect measurement)
Analytical methods
colorimetry, turbidimetry, latex agglutination, homogeneous enzyme immunoassay, indirect ISE
Simultaneous analyte processing
60 photometric tests + 3 ISE, 120 on-board preprogrammed tests
Throughput
400 photometric tests per hour; maximum 800 with ISE
Ion-selective ISE module throughput
200 samples per hour. Maximum tests per hour: 600 (ISE only)
Sample types
serum, plasma, urine and others
Sample transport
racks holding 10 samples each (barcodes on primary tubes and racks); capacity of 80 samples; continuous loading
Sample tubes
primary and secondary tubes; diameter 11.5-16 mm; height 55-102 mm, built-in micro sample cups.
STAT samples
22 STAT sample positions on a refrigerated STAT rotor. Easy interruption between tests. Automatic rerun capability.
Sample volume
1-25 µl in 0.1 µl steps (1-25 µl for reruns)
Reagent capacity
76 positions (R1+R2, detergent position). Holds 15, 30 and 60 ml bottles.
Reagent storage
refrigerated (4-12 °C)
Reagent volume
R1: 10-250 µl; R2: 10-250 µl (in 1 µl steps)
Total reaction volume
90-350 µl
Reaction cuvette
quartz cuvettes with unlimited service life.
Reaction time
up to 8 minutes 37.5 seconds.
Reaction incubation
37 °C, dry bath.
Photometric system
direct measurement through the reaction cuvettes (optical density 0-3.0), monochromatic and bichromatic measurements possible.
Wavelength
13 wavelengths from 340 to 800 nm
Calibration
automatic calibration, on-board refrigeration of calibrators; master calibration specified by two-dimensional barcode.
Quality control
automatic quality control, refrigerated quality control positions.
Rerun
1) automatic and manual rerun; 2) automatic rerun with unchanged, reduced or increased sample volume; 3) reflex testing.
Sample predilution
fixed dilution ratios of 3, 5, 10, 15, 20, 25, 50, 76 and 100.
Test requests
online checking of individual test and profile orders using a mouse, function keys or touch screen.
Sample integrity
lipemia, hemolysis and icterus analysis; clot detection and protection against pipettor failures.
Network settings
RS232C. Full unidirectional and bidirectional communication possible.
Software
Windows 7®
Data storage
100 000 samples.
Reaction data
200 000 tests.
Dimensions (W x H x D), analyzer
1 450 x 1 205 x 760
Power supply
100-240 V; 60 Hz, <3.5 kVA