Medtronic NIM-Response 3.0 intraoperative nerve monitoring system REF: 8253002

Medtronic NIM-Response 3.0 EMG-based intraoperative nerve monitoring system (REF: 8253002) with patient simulator, muting detector and NIM module.

Price on request

Add this device to your quote list to request its price.

ТОО "FSA KZ (ФСА КЗ)", Almaty, Kazakhstan, BIN 210940036794

Brand
Medtronic
Condition
Used, tested, and in good working condition
Model
NIM-Response 3.0
Category
Neurology

Specifications

Medtronic NIM-Response 3.0 REF8253002
Nim Muting Detector REF68L1204
Nim-Response 3.0 REF8253200
System REF8253002
Patient Simulator REF8253600
Muting Detector REF68L1204
NIM Module REF8253200
Monitoring TechnologyElectromyography (EMG)
Ideal forHospitals, clinics, surgical centres

Description

Includes:

  • Medtronic NIM-Response 3.0 REF: 8253002
  • Medtronic Nim 3.0 Patient Simulator REF: 8253600
  • Nim Muting Detector REF: 68L1204
  • Nim-Response 3.0 REF: 8253200

The Medtronic NIM-Response® 3.0 Intraoperative Nerve Monitoring System (REF: 8253002) is a leading intraoperative nerve monitoring (IONM) system designed to help surgeons identify, monitor, and protect motor nerves during complex surgical procedures. Manufactured by Medtronic, the global leader in surgical technologies, the NIM-Response 3.0 enhances patient safety by providing continuous real-time electromyographic (EMG) monitoring throughout surgery.

This complete system includes the Medtronic NIM 3.0 Patient Simulator (REF: 8253600), NIM Muting Detector (REF: 68L1204), and NIM-Response 3.0 Module (REF: 8253200), providing a comprehensive solution for accurate nerve integrity monitoring in ENT, thyroid, parathyroid, neurosurgical, spinal, and head & neck procedures.

Included Equipment

Medtronic NIM-Response® 3.0 System

REF: 8253002

Medtronic NIM 3.0 Patient Simulator

REF: 8253600

NIM Muting Detector

REF: 68L1204

NIM-Response® 3.0 Module

REF: 8253200

Key Features

Advanced Intraoperative Nerve Monitoring (IONM)

Provides continuous real-time EMG monitoring to assist in nerve identification and preservation during surgery.

Enhanced Patient Safety

Helps reduce the risk of nerve injury during delicate surgical procedures.

Real-Time Electromyography (EMG)

Offers immediate feedback on nerve function, allowing surgeons to make informed intraoperative decisions.

Complete Testing & Calibration Package

Includes a genuine Medtronic Patient Simulator for system verification and performance testing.

NIM Muting Detector

Improves operating room workflow by automatically managing interference and enhancing monitoring accuracy.

User-Friendly Interface

Designed for intuitive operation with clear EMG displays and simplified clinical workflow.

Trusted Medtronic Technology

Widely used in hospitals and surgical centers worldwide for nerve monitoring procedures.

Technical Specifications

Manufacturer: Medtronic

Model: NIM-Response® 3.0

System REF: 8253002

Patient Simulator REF: 8253600

Muting Detector REF: 68L1204

NIM Module REF: 8253200

Device Type: Intraoperative Nerve Monitoring System (IONM)

Monitoring Technology: Electromyography (EMG)

Clinical Applications

Thyroid Surgery

Parathyroid Surgery

ENT Surgery

Neurosurgery

Spine Surgery

Skull Base Surgery

Head & Neck Surgery

Otolaryngology Procedures

Hospital Operating Rooms

Surgical Centers

Key Benefits

Complete Medtronic NIM-Response® 3.0 system

Real-time EMG nerve monitoring

Enhanced nerve preservation

Improved surgical safety

Includes patient simulator and muting detector

Reliable Medtronic performance

Ideal for ENT, thyroid, spine, and neurosurgical procedures

Why Choose the Medtronic NIM-Response® 3.0?

The Medtronic NIM-Response® 3.0 is one of the world's most trusted intraoperative nerve monitoring systems, providing exceptional EMG accuracy, dependable performance, and advanced nerve protection during surgery. Complete with the Patient Simulator, Muting Detector, and NIM-Response Module, this package is an ideal solution for hospitals and surgical facilities seeking a comprehensive IONM platform.

The Medtronic NIM-Response 3.0 is a reliable piece of equipment designed for intraoperative nerve monitoring. It is essential in neurosurgical and otolaryngological procedures, ensuring nerve integrity and reducing the risk of nerve damage during surgery. This system is equipped with advanced nerve signal processing capabilities, providing real-time feedback to surgeons.

The package includes the Medtronic NIM 3.0 Patient Simulator and the Nim Muting Detector. The patient simulator, referenced as REF: 8253600, is crucial for pre-procedural testing and calibration, ensuring that the system is functioning accurately before each surgery. The Nim Muting Detector with REF: 68L1204 allows for minimizing interruption in nerve signal monitoring, offering uninterrupted operation throughout procedures.

Though used, this equipment is maintained to provide dependable performance and accuracy in a clinical setting. It's an ideal choice for healthcare providers focusing on patient safety and surgical outcomes.

Similar devices

Whole category