Medtronic NIM-Response 3.0 nerve monitoring system

Medtronic NIM-Response 3.0 intraoperative nerve monitoring system with NIM 3.0 patient simulator (REF 8253600) and NIM muting detector (REF 68L1204 A).

Price on request

Add this device to your quote list to request its price.

ТОО "FSA KZ (ФСА КЗ)", Almaty, Kazakhstan, BIN 210940036794

Brand
Medtronic
Condition
Used, tested, and in good working condition
Model
NIM-Response 3.0 Medtronic
Category
Neurology

Specifications

ModelNIM-Response 3.0
Ideal forHospitals, clinics, surgical centers

Description

Includes:

  • Medtronic NIM-Response 3.0
  • NIM 3.0 Patient Simulator, REF: 8253600
  • NIM Muting Detector, REF: 68L1204 A

Medtronic NIM-Response 3.0 Nerve Monitoring System, Patient Simulator & Muting Detector Included

The Medtronic NIM-Response 3.0 Nerve Monitoring System is a professional intraoperative nerve monitoring system designed to assist clinicians with monitoring nerve and muscle activity during appropriate surgical procedures.

Manufactured by Medtronic, the NIM-Response 3.0 is designed for use in specialist surgical environments where intraoperative nerve monitoring is required. The system is particularly relevant to ENT, head and neck, thyroid, parotid, skull base and other procedures involving nerves at risk, subject to the appropriate clinical configuration and use.

This configuration includes a NIM 3.0 Patient Simulator and NIM Muting Detector, providing additional components for system testing and compatible monitoring workflows.

Included Equipment

Medtronic NIM-Response 3.0

Main System

  • Medtronic NIM-Response 3.0 Nerve Monitoring System

Included Accessories

  • NIM 3.0 Patient Simulator, REF: 8253600
  • NIM Muting Detector, REF: 68L1204 A

Key Features

  • Intraoperative Nerve Monitoring: The Medtronic NIM-Response 3.0 is designed to provide intraoperative monitoring of nerve and muscle activity during compatible surgical procedures.
  • Nerve & Muscle Activity Monitoring: The system is designed to assist surgical teams in monitoring neuromuscular responses during procedures where nerve identification and monitoring are clinically relevant.
  • ENT & Head and Neck Surgery: The NIM platform is particularly associated with procedures in ENT, otolaryngology and head and neck surgery, where monitoring of nerves may be required.
  • Patient Simulator Included: The included NIM 3.0 Patient Simulator, REF: 8253600, provides a dedicated component for compatible system testing and verification workflows.
  • Muting Detector Included: The NIM Muting Detector, REF: 68L1204 A, is included as part of this configuration and is designed for use with compatible NIM monitoring equipment.

Clinical Applications

The Medtronic NIM-Response 3.0 may be used for appropriate nerve monitoring applications including:

  • ENT Surgery
  • Otolaryngology
  • Head and Neck Surgery
  • Thyroid Surgery
  • Parotid Surgery
  • Skull Base Surgery
  • Nerve Monitoring Procedures
  • Intraoperative Neuromonitoring
  • Electrophysiological Monitoring
  • Specialist Surgical Procedures

Technical Specifications

Manufacturer
Medtronic
Model
NIM-Response 3.0
Device Type
Intraoperative Nerve Monitoring System
Patient Simulator
NIM 3.0 Patient Simulator
Simulator REF
8253600
Muting Detector
NIM Muting Detector
Detector REF
68L1204 A
Application
Intraoperative Nerve Monitoring

Included Components

1. Medtronic NIM-Response 3.0: Professional intraoperative nerve monitoring platform.

2. NIM 3.0 Patient Simulator, REF: 8253600: Included patient simulator for compatible testing and system verification.

3. NIM Muting Detector, REF: 68L1204 A: Included muting detector designed for compatible NIM system applications.

Key Benefits

  • Genuine Medtronic NIM-Response 3.0
  • Professional intraoperative nerve monitoring system
  • Suitable for compatible ENT and head & neck procedures
  • NIM 3.0 Patient Simulator included
  • Patient Simulator REF: 8253600
  • NIM Muting Detector included
  • Muting Detector REF: 68L1204 A
  • Suitable for hospitals and specialist surgical centers
  • Suitable for used medical equipment applications

Why Choose the Medtronic NIM-Response 3.0?

The Medtronic NIM-Response 3.0 Nerve Monitoring System is a specialist surgical monitoring platform designed for appropriate intraoperative nerve monitoring applications. Supplied with the NIM 3.0 Patient Simulator, REF: 8253600, and NIM Muting Detector, REF: 68L1204 A, this configuration provides additional components for compatible system testing and monitoring workflows.

It is particularly relevant to buyers searching for a Medtronic NIM-Response 3.0, Medtronic NIM nerve monitor, NIM 3.0 nerve monitoring system, intraoperative nerve monitoring equipment, Medtronic neuromonitoring equipment or used Medtronic NIM system.

The Medtronic NIM-Response 3.0 is a reliable tool in neurological monitoring, offering advanced features for intraoperative nerve monitoring. Designed for precision, this used unit includes the NIM 3.0 Patient Simulator, allowing for efficient testing and calibration to ensure performance accuracy during medical procedures. It operates effectively, supporting patient safety by aiding in the identification and protection of nerve function.

Additionally, the package comes with the NIM Muting Detector (REF: 68L1204), which helps in reducing interference, providing clearer signals during surgeries, thus enhancing monitoring efficacy. This system is an optimal choice for neurosurgeons looking for a dependable intraoperative monitoring solution that supports improved surgical outcomes. Known for its durability and precision, the Medtronic NIM-Response 3.0 stands out as a valuable addition to any surgical suite focused on patient neurological function.